The blow-down control system is controlled by computer and consists of the following sub-systems:
- the pressure regulating valve control subsystem
- the transonic Mach number control (top and bottom flaps and blow-off valve) subsystem
- the software protection against overloading the balance and sting
- the model angle of attack control subsystem
- the blow - down sequence control subsystem
- the Schlieren control subsystem
- the scanivalve control unit.