Laboratory Testing Capabity -1

Print

 

hydraulic power generator:

maximum operating pressure:
315 bar
maximum flow: 100 l/min

 

control panel allows:

  • monitoring and maintaining constant oil pressure
  • monitoring and control of oil temperature
  • flow monitoring: variable flow
  • automatic stop in case of emergency

capability_1_1

 

particle analyser Hydac International

for intermittent measurement of the particulate contamination

 

  • decontamination capabilities − about 200l/day
      up to 2-3 NAS 1638 class
  • temperature range:  
      +10 ÷ +70°C
  • determinations of liquid samples − inclusively online

capability_1_2